Patented pressurized fluid container

Store it sealed. Dispense it without a pump.

SquareCell is a patented, pressurized, baffled fluid container for fuels, lubricants, and other fluids. It holds product under an inert gas blanket, dispenses at up to 100 gallons per minute with no pump or power, and contains spills with 110% weatherproof secondary containment.

SquareCell pressurized fluid container with the lid open, showing the dispensing hose and controlsSQUARECELL 370 · STANDARD UNIT
Capacity
370gal
Dispensing
100GPM max
Containment
110%secondary
External power
Noneneeded
US Patent
10,745,191B2
Quick answer

What is SquareCell?

SquareCell is a double-walled, fully enclosed fluid container that works like a storage tank and an intermediate bulk container (IBC) in one. A compressed gas cartridge pressurizes the inner tank, so product dispenses on demand without an electric pump. While stored, product sits under a blanket of inert gas instead of open air, which cuts contamination, evaporation, condensation, and vent emissions.

It is engineered to meet NFPA 30, UL 142, and US DOT standards, and is made by SquareCell LLC in Abilene, Texas.

How it works

Pressure does the work a pump used to do.

  1. Fill and blanket

    Product goes into the removable inner tank, and inert gas fills the space above it. Nothing vents to the atmosphere, so contaminants stay out and emissions stay in.

  2. Pressurize

    A compressed gas cartridge pressurizes the container. Internal baffles steady the fluid while the unit is moved or dispensing.

  3. Dispense anywhere

    Open the valve and product flows at up to 100 GPM. No pump, no generator, no outlet. Vacuum loading also clears tanks and lines efficiently.

  4. Contain

    The outer wall holds 110% of the inner tank's capacity, so a leak stays inside the enclosed, weatherproof housing.

Read the full explanation of how SquareCell works

How SquareCell worksCutaway diagram: a compressed gas cartridge pressurizes the inner tank, an inert gas blanket sits above the fluid, internal baffles steady the load, fluid dispenses through a hose, and the outer wall forms 110 percent secondary containment. 01 Gas cartridgepressurizes the tank 02 Inert gasblanket, no venting 03 Bafflessteady the fluid 04 Dispenseup to 100 GPM 05 Outer wall110% containment
Illustrative cutaway. Not to scale.

Why SquareCell

Five reasons crews switch from tanks and totes.

Most containers either store product or dispense it. SquareCell does both, and protects the product and the ground underneath while it does.

01 · Pressurized unloading

No pump. No power. Up to 100 GPM.

Pressurized unloading and storage eliminate conventional pumps, and vacuum loading clears tanks and lines efficiently while preserving product integrity.

02 · Product integrity

Product stays the way it arrived

An inert gas blanket protects stored product from contamination, evaporation, and condensation, from storage through dispensing.

03 · Containment

110% weatherproof containment

Fully enclosed, double-walled construction guards against spills, contamination, and harsh weather.

04 · Footprint

Compact and transportable

A 45 1/8 in. square footprint is efficient to haul and helps maximize warehouse and yard space.

05 · Modular

Built around your application

Internal baffles and a modular, customizable build adapt SquareCell to the fluid and the site.

White pickup truck towing a SquareCell container on a utility trailer

Product where you need it

Hitch it up. Dispense on arrival.

SquareCell rides on a standard trailer and starts dispensing the moment it lands, with no hookups to wait for.

Compare

SquareCell vs. IBC totes and conventional tanks

Tanks and totes cost less to buy. SquareCell is built for the jobs where safety, containment, and product integrity cost more when they fail.

FeatureSquareCellTypical IBC toteConventional tank
DispensingPressurized, up to 100 GPM, no pump or powerGravity drain or separate pumpGravity or separate pump
Product protectionInert gas blanket; no venting to airVented or open to air when dispensingTypically vented to atmosphere
Secondary containment110%, built in, fully enclosedUsually none without a spill palletOften requires a separate dike or berm
Weather exposureFully enclosed, weatherproof housingExposed tote and cageExposed tank and fittings
Transport & footprintCompact square footprint; trailer-readyCompact; stackable when emptyLarger footprint; often fixed on a stand
StandardsEngineered to NFPA 30, UL 142, US DOTVaries by toteVaries by tank
Entry costHigher than a typical IBCLowestLower than SquareCell
IBC and conventional tank columns describe typical products in each category; individual models vary.

See the full SquareCell comparison

FAQ

Common questions

What is SquareCell?

SquareCell is a patented, pressurized, baffled fluid container made by SquareCell LLC of Abilene, Texas. It stores fuels, lubricants, and other fluids under an inert gas blanket and dispenses them under pressure without a pump or outside power. It serves the storage tank and intermediate bulk container (IBC) markets.

How does SquareCell dispense fluid without a pump?

A compressed gas cartridge pressurizes the container and pushes product out through the dispensing line at up to 100 gallons per minute. Because there is no electric pump, the unit needs no outside power source and can be placed in remote or difficult locations.

What is an inert gas blanket and why does it matter?

Instead of venting to the atmosphere, SquareCell stores product under a layer of inert gas. This keeps air, moisture, and contaminants out, reduces evaporation and condensation, and virtually eliminates escaping vent gases from hazardous liquids.

How much does a SquareCell hold?

The standard SquareCell holds 370 gallons. It measures 80 in. high by 45 1/8 in. wide by 45 1/8 in. long and weighs 2,075 lbs. empty. 100, 250, and 500-gallon versions are pending final engineering.

What does 110% secondary containment mean?

The outer wall of SquareCell can hold 110% of the inner tank's capacity. If the inner tank leaks, the fluid stays inside the fully enclosed, double-walled unit rather than reaching the ground, water, or wildlife.

What standards does SquareCell meet?

SquareCell is engineered to meet NFPA 30 (Flammable and Combustible Liquids Code), UL 142 (steel aboveground tanks for flammable and combustible liquids), and US DOT requirements.

Read all SquareCell FAQs

Talk to SquareCell

Put product where you need it, when you need it.

Tell us what you store, how much, and where. We will help you decide whether SquareCell fits your site.